﻿{"id":6496,"date":"2016-01-20T17:44:00","date_gmt":"2016-01-20T16:44:00","guid":{"rendered":"http:\/\/www.flycaravelle.com\/?page_id=6496"},"modified":"2016-01-20T17:44:32","modified_gmt":"2016-01-20T16:44:32","slug":"ua2-english-electrical-panel","status":"publish","type":"page","link":"https:\/\/www.flycaravelle.com\/sv\/pilot-login\/ua2-english-electrical-panel\/","title":{"rendered":"UA2 &#8211; English &#8211; Electrical Panel"},"content":{"rendered":"<p>Some basic info about the electrical system can be found here:<\/p>\n<style type=\"text\/css\">\n\t\t\t\t#hotspot-6485 .hotspots-image-container {\n\t\t\t\t\tbackground: #ffffff;\n\t\t\t\t}\n\n\t\t\t\t#hotspot-6485 .hotspots-placeholder,\n\t\t\t\t.featherlight .featherlight-content.lightbox-6485,\n\t\t\t\t.qtip.tooltip-6485 {\n\t\t\t\t\tbackground: #dbdbdb;\n\t\t\t\t\tborder: 0 #dbdbdb solid;\n\t\t\t\t\tcolor: #000000;\n\t\t\t\t}\n\t\t\t\t.qtip.tooltip-6485 .qtip-icon .ui-icon {\n\t\t\t\t\tcolor: #000000;\n\t\t\t\t}\n\n\t\t\t\t#hotspot-6485 .hotspot-title,\n\t\t\t\t.featherlight .featherlight-content.lightbox-6485 .hotspot-title,\n\t\t\t\t.qtip.tooltip-6485 .hotspot-title {\n\t\t\t\t\tcolor: #000000;\n\t\t\t\t}<\/style><div class=\"hotspots-container  layout-tooltip event-hover\" id=\"hotspot-6485\"><div class=\"hotspots-interaction\"><div class=\"hotspots-image-container\"><img decoding=\"async\" width=\"1000\" height= \"802\" src=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/main.jpg\" class=\"hotspots-image\" usemap=\"#hotspots-image-6485\" data-event-trigger=\"hover\" data-highlight-color=\"#ff0000\" data-highlight-opacity=\"0.41\" data-highlight-border-color=\"#ffffff\" data-highlight-border-width=\"1\" data-highlight-border-opacity=\"0.41\" data-no-lazy=\"1\" \/><\/div><\/div><map name=\"hotspots-image-6485\" class=\"hotspots-map\"><area shape=\"poly\" coords=\"65,629,72,629,80,639,99,643,124,638,134,628,141,628,143,692,124,705,100,707,77,704,64,696\" href=\"#hotspot-hotspot-6485-0\" title=\"Battery selector switch\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"96,118,112,119,120,128,122,157,109,167,91,165,77,153,75,135,85,124\" href=\"#hotspot-hotspot-6485-1\" title=\"Still figuring out what that is...\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"100,223,110,225,124,233,131,256,124,273,108,281,93,280,82,272,71,255,71,241,80,228\" href=\"#hotspot-hotspot-6485-2\" title=\"Magnetic Indicator normal battery\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"222,224,300,225,313,227,320,234,324,242,326,261,320,272,311,276,300,278,221,279,206,274,197,263,195,249,198,237,208,227\" href=\"#hotspot-hotspot-6485-3\" title=\"Stand-by batteries\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"50,178,129,180,130,192,132,213,51,214\" href=\"#hotspot-hotspot-6485-4\" title=\"Normal Battery Bus\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"192,194,490,195,491,216,192,215\" href=\"#hotspot-hotspot-6485-5\" title=\"Stand-by Battery Bus\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"556,197,928,196,929,216,556,216\" href=\"#hotspot-hotspot-6485-6\" title=\"Generator Bus\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"522,178,536,183,549,193,554,211,549,226,532,237,511,234,498,223,494,203,504,186\" href=\"#hotspot-hotspot-6485-7\" title=\"Magnetic Indicator\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"107,363,121,367,134,372,150,387,159,406,158,428,150,441,134,453,117,460,95,462,75,453,60,438,53,416,53,393,64,380,83,369\" href=\"#hotspot-hotspot-6485-8\" title=\"Ammeter Normal Battery\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"423,540,432,542,444,555,447,571,438,581,418,585,403,580,395,564,400,547,411,540\" href=\"#hotspot-hotspot-6485-9\" title=\"Emergency Battery\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"390,640,449,640,464,674,448,709,389,709,372,675\" href=\"#hotspot-hotspot-6485-10\" title=\"Voltage selector\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"423,367,448,376,468,392,479,424,468,449,451,464,421,469,396,465,374,444,368,419,375,394,394,376\" href=\"#hotspot-hotspot-6485-11\" title=\"Voltmeter\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"903,97,920,99,932,112,936,126,931,146,919,155,900,156,885,145,877,129,884,109,893,102\" href=\"#hotspot-hotspot-6485-12\" title=\"PP33\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"826,100,842,102,853,116,855,134,850,144,838,151,827,152,814,153,803,144,799,131,801,113,811,104\" href=\"#hotspot-hotspot-6485-13\" title=\"PP32\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"743,96,767,102,776,121,773,140,761,153,742,157,722,148,717,122,725,103\" href=\"#hotspot-hotspot-6485-14\" title=\"PP31\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"666,100,680,105,690,119,688,142,682,150,666,154,654,149,645,138,642,129,643,117,650,107\" href=\"#hotspot-hotspot-6485-15\" title=\"PP42\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"583,97,603,107,612,121,610,142,600,153,585,156,564,149,556,141,556,122,562,106\" href=\"#hotspot-hotspot-6485-16\" title=\"PP41\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"581,226,593,229,606,240,611,260,607,275,596,281,580,285,565,280,555,267,556,243,566,230\" href=\"#hotspot-hotspot-6485-17\" title=\"Left generator\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"742,224,756,228,764,233,771,249,772,262,764,275,752,280,740,280,731,280,721,272,714,260,712,246,722,231,730,227\" href=\"#hotspot-hotspot-6485-18\" title=\"Right generator\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"901,400,914,402,923,419,923,432,917,438,906,442,896,440,891,435,884,427,884,414,891,405\" href=\"#hotspot-hotspot-6485-19\" title=\"Ground Power plugged in\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"905,223,921,230,932,242,934,263,927,277,917,283,897,283,887,276,877,261,878,245,887,233\" href=\"#hotspot-hotspot-6485-20\" title=\"Magnetic Indicator ground power\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"581,362,606,367,619,378,633,396,639,422,631,446,607,467,581,475,548,465,531,449,524,425,526,395,539,382,559,367\" href=\"#hotspot-hotspot-6485-21\" title=\"Left generator ammeter\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"738,362,757,363,771,371,786,388,793,408,794,428,785,452,768,463,747,469,720,464,702,454,689,438,684,420,685,405,697,384,707,373,722,366\" href=\"#hotspot-hotspot-6485-22\" title=\"Right generator ammeter\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"550,668,552,716,556,726,564,739,578,741,592,737,597,727,602,718,601,668,712,671,713,725,722,738,735,749,754,743,763,731,762,671,733,670,720,670,602,668,588,668,570,668,562,668\" href=\"#hotspot-hotspot-6485-23\" title=\"Generator overheat warning\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"660,496,670,498,678,503,680,512,681,524,673,535,660,538,645,533,635,519,641,503,650,497\" href=\"#hotspot-hotspot-6485-24\" title=\"Generator reset switch\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"557,562,715,565,715,566,762,565,763,670,717,669,718,565,602,564,603,665,556,664,557,596,556,577,556,570\" href=\"#hotspot-hotspot-6485-25\" title=\"Generator control switches\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"898,700,909,703,914,713,917,724,915,732,908,736,895,738,883,732,876,720,884,703\" href=\"#hotspot-hotspot-6485-26\" title=\"Transformer selector\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"897,510,917,511,931,519,947,536,954,555,953,578,944,592,928,608,906,615,881,614,864,605,851,588,842,571,844,550,854,528,870,517\" href=\"#hotspot-hotspot-6485-27\" title=\"Inverter voltmeter\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"894,745,905,745,911,753,911,765,905,775,891,775,882,767,883,753\" href=\"#hotspot-hotspot-6485-28\" title=\"Transformer Voltage\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"571,499,560,508,560,522,565,530,580,540,593,543,659,560,663,558,738,542,742,542,754,542,763,535,764,521,759,507,748,501,732,500,724,508,721,519,723,527,723,534,729,538,730,542,658,561,592,543,604,528,602,509,588,500\" href=\"#hotspot-hotspot-6485-29\" title=\"Generator trip warning\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"519,501,512,502,505,510,505,518,510,524,523,527,532,523,534,516,534,509,659,480,786,512,788,521,796,531,812,530,817,519,811,507,799,503,788,511,659,480,533,508,527,501\" href=\"#hotspot-hotspot-6485-30\" title=\"Generator trip warning test\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"261,366,283,369,297,378,313,395,320,413,319,436,309,455,297,463,278,469,258,471,238,464,221,454,214,433,211,408,212,393,228,377,240,368\" href=\"#hotspot-hotspot-6485-31\" title=\"Ammeter stand-by batteries\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"464,97,481,97,493,122,485,143,471,152,451,152,438,138,436,121,447,102\" href=\"#hotspot-hotspot-6485-32\" title=\"PP21\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"382,95,402,102,412,120,412,143,397,156,380,160,356,147,348,128,357,106,369,97\" href=\"#hotspot-hotspot-6485-33\" title=\"PP22\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"298,93,317,101,328,116,328,137,320,149,305,156,289,153,273,136,269,123,276,104,284,99\" href=\"#hotspot-hotspot-6485-34\" title=\"PP23\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"220,95,236,98,253,114,252,140,237,152,217,155,203,149,195,130,198,110,204,102\" href=\"#hotspot-hotspot-6485-35\" title=\"PP24\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"163,46,179,50,191,72,190,90,176,102,159,104,145,95,134,81,133,66,143,48\" href=\"#hotspot-hotspot-6485-36\" title=\"PP11 Essential Bus\" data-action=\"\" target=\"\" class=\"more-info-area\"><area shape=\"poly\" coords=\"160,176,182,185,191,203,187,224,174,232,155,233,143,225,135,202,144,185\" href=\"#hotspot-hotspot-6485-37\" title=\"Magnetic Indicator\" data-action=\"\" target=\"\" class=\"more-info-area\"><\/map><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-0\"><h2 class=\"hotspot-title\">Battery selector switch<\/h2><div class=\"hotspot-thumb\"><img loading=\"lazy\" decoding=\"async\" width=\"291\" height=\"169\" src=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/groundpower.jpg\" class=\"attachment-medium size-medium\" alt=\"\" \/><\/div><div class=\"hotspot-content\"><p>PRISE PARC (Ground Power): The aircraft's electrical systems are supplied by the ground power. BAT BORD (Normal battery) and BAT SECURITE (stand-by battery) are isolated. Generators cannot be connected. If the ground power exceeds 32V for more than 3 seconds it is disconnected.<br \/>\nCOUPE (OFF): Aircraft's electrical system are de-energized.<br \/>\nRESEAU BORD (Plane Bat): BAT BORD (normal battery) is connected to bus PP11 1 and 2, starter system<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-1\"><h2 class=\"hotspot-title\">Still figuring out what that is...<\/h2><div class=\"hotspot-content\"><p>Manuals do not provide adequate description.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-2\"><h2 class=\"hotspot-title\">Magnetic Indicator normal battery<\/h2><div class=\"hotspot-content\"><p>This magnetic indicator will show | when the switch below it set to \"RESEAU BORD\". The ammeter will show current being drawn.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-3\"><h2 class=\"hotspot-title\">Stand-by batteries<\/h2><div class=\"hotspot-thumb\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"221\" src=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/batteryselector-300x221.jpg\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/batteryselector-300x221.jpg 300w, https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/batteryselector.jpg 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/div><div class=\"hotspot-content\"><p>There are actually 5 stand-by batteries arranged in two groups with three batteries in one group and two in another. Total capacity is 80Ah. When the standby battery handle is in its normal 28V position, the batteries are connected in parallel. Each group will then be individually connected to the stand-by battery bus (PP2) provided the battery selector is in the RESEAU BORD position. These magnetic indicators show whether the batteries are connected. The batteries will either deliver power to ghe bus or be charge from the bus. On ground with the nose gear commpressed charging is limited by a resistor.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-4\"><h2 class=\"hotspot-title\">Normal Battery Bus<\/h2><div class=\"hotspot-content\"><p>Also called PP1. It is connected to the normal battery, but will receive power from PP3 (Generator Bus) via PP2 (Stand-by Battery Bus) whenever PP3 is energized.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-5\"><h2 class=\"hotspot-title\">Stand-by Battery Bus<\/h2><div class=\"hotspot-content\"><p>Also called PP2. It is connected to the stand-by batteries, but will receive power from PP3 (Generator Bus) whenever this bus is energized.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-6\"><h2 class=\"hotspot-title\">Generator Bus<\/h2><div class=\"hotspot-content\"><p>Also called PP3. It is energized by the generators or on ground by the 28V DC ground power source. It can never be powered by any other DC power source.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-7\"><h2 class=\"hotspot-title\">Magnetic Indicator<\/h2><div class=\"hotspot-thumb\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"181\" src=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/magindi-on-300x181.jpg\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/magindi-on-300x181.jpg 300w, https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/magindi-on.jpg 434w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/div><div class=\"hotspot-content\"><p>Shows a line when the Generator Bus poweres the Stand-by Battery Bus.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-8\"><h2 class=\"hotspot-title\">Ammeter Normal Battery<\/h2><div class=\"hotspot-content\"><p>The ammeter for the normal battery. This battery has a 16Ah capacity. In case of engine start with batteries this battery assures the igniters are powered.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-9\"><h2 class=\"hotspot-title\">Emergency Battery<\/h2><div class=\"hotspot-thumb\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"137\" src=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/GEN-switch-300x137.jpg\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/GEN-switch-300x137.jpg 300w, https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/GEN-switch.jpg 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/div><div class=\"hotspot-content\"><p>When this push button is depressed it indicates the voltage of the Emergency Battery (0.9Ah). It will be connected to PP17 and the emergency lights when the BAT switch on the pedestal (see above, it is the left one of the two in red) is in the OFF position. It is charged by inverter 1 or 2 through a transformer.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-10\"><h2 class=\"hotspot-title\">Voltage selector<\/h2><div class=\"hotspot-content\"><p>Shows voltage of the selected system:<br \/>\nGENE. D : right generator<br \/>\nGENE. G : left generator<br \/>\nRESEAU : ground power<br \/>\nBAT.BORD normal battery<br \/>\nBS.1 stand-by battery 1<br \/>\nBS.2 stand-by battery 2<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-11\"><h2 class=\"hotspot-title\">Voltmeter<\/h2><div class=\"hotspot-content\"><p>Displays the voltage of the selected system.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-12\"><h2 class=\"hotspot-title\">PP33<\/h2><div class=\"hotspot-content\"><p>If this magnetic indicators shows a line it means the following systems are powered:<\/p>\n<ul>\n<li>Waster water system<\/li>\n<li>Part of the cabin lights<\/li>\n<\/ul>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-13\"><h2 class=\"hotspot-title\">PP32<\/h2><div class=\"hotspot-content\"><p>If this bus powered, the following system are energized:<\/p>\n<ul>\n<li>Aft Galley<\/li>\n<li>Reading lights<\/li>\n<li>Aisle and toilet lights<\/li>\n<li>Razor outputs<\/li>\n<li>Water heating (right side)<\/li>\n<li>Some windshields<\/li>\n<\/ul>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-14\"><h2 class=\"hotspot-title\">PP31<\/h2><div class=\"hotspot-content\"><p>Powers the following systems:<\/p>\n<ul>\n<li>Panel lights<\/li>\n<li>Passenger entrance<\/li>\n<li>Left wing light<\/li>\n<li>Front water heater<\/li>\n<li>Angle of attack indicator<\/li>\n<li>Artifical feel<\/li>\n<li>Both cockpit ventilation fans<\/li>\n<li>Reading lights cockpit<\/li>\n<li>Part of the cabin lights<\/li>\n<li>Toilet lights<\/li>\n<li>UA panel lights<\/li>\n<li>Engine lights<\/li>\n<li>Copilot windhield heatings<\/li>\n<li>Ice detector<\/li>\n<li><\/li>\n<\/ul>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-15\"><h2 class=\"hotspot-title\">PP42<\/h2><div class=\"hotspot-content\"><p>Powers the following systems:<\/p>\n<ul>\n<li>Flasher &amp;. landing lights and motorCabin RH incand. light<\/li>\n<li>Radio panel light<\/li>\n<li>Instrument panel red lights<\/li>\n<li>VHF2, ADF2, Selcal, VOR2<\/li>\n<li>Tape reproducer &amp; cockpit loudspeakers<\/li>\n<li>Flight director 2<\/li>\n<li>Normal inverter control<\/li>\n<li>ATC, DME1 (not installed on Poitou), DME2<\/li>\n<\/ul>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-16\"><h2 class=\"hotspot-title\">PP41<\/h2><div class=\"hotspot-content\"><p>Powers the following systems:<\/p>\n<ul>\n<li>Cpt outb. windsh. heat &amp; windsh. wiper<\/li>\n<li>Anti-collision light<\/li>\n<li>Marker &amp;. VOR I<\/li>\n<li>Alt. Inverter control<\/li>\n<li>Flight Director 1<\/li>\n<li>Ground power indicating light (test)<\/li>\n<li>Artifical feel pitot heat<\/li>\n<li>Radar<\/li>\n<\/ul>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-17\"><h2 class=\"hotspot-title\">Left generator<\/h2><div class=\"hotspot-content\"><p>Indicates whether the left engine's generator supplies the generator bus (PP3)<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-18\"><h2 class=\"hotspot-title\">Right generator<\/h2><div class=\"hotspot-content\"><p>Indicates whether the right generator supplies the Generator Bus (PP3)<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-19\"><h2 class=\"hotspot-title\">Ground Power plugged in<\/h2><div class=\"hotspot-content\"><p>When this lights illuminates green, the ground power is plugged in.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-20\"><h2 class=\"hotspot-title\">Magnetic Indicator ground power<\/h2><div class=\"hotspot-content\"><p>Shows a line when the ground power is supplying the Generator bus (PP3). This is archived by switching the lower left switch of this panel to \"PRISE DE PARC\".<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-21\"><h2 class=\"hotspot-title\">Left generator ammeter<\/h2><div class=\"hotspot-content\"><p>Shows how much amps the generators puts out.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-22\"><h2 class=\"hotspot-title\">Right generator ammeter<\/h2><div class=\"hotspot-content\"><p>Shows how much amps the generator puts out<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-23\"><h2 class=\"hotspot-title\">Generator overheat warning<\/h2><div class=\"hotspot-content\"><p>If a generator becomes overheated a thermos switch will close and activate the corresponding generator SURCHAUFFE (overheat) warning light together with the GENE master warning light and the chime. By placing the affected generator control switch in position OFF, the master warning light will go out and the chime be rearmed. The OVERHEAT warning light on the DC control panel will remain on as long as the overheat condition persists.<br \/>\nEach generator overheat warning circuit can be tested by depressing a TEST button located above each SURCHAUFFE warning light.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-24\"><h2 class=\"hotspot-title\">Generator reset switch<\/h2><div class=\"hotspot-content\"><p>It is spring-loaded to centre-off position.<br \/>\nWhen actuated towards either generator tripped warning light, it will energize the reset coil of the corresponding generator main circuit breaker and bring the generator back online.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-25\"><h2 class=\"hotspot-title\">Generator control switches<\/h2><div class=\"hotspot-content\"><p>The two generator control switches with positions ON (NORMALE) and OFF (COUPE) are located on the DC control panel and are placarded LH and RH DC GENERATORS. They control the main contactor of the respective generator. With a generator control switch in OFF position, the main contactor for the corresponding generator will always be open and the generator will be disconnected from PP3. With the switch in ON position, the<br \/>\nmain contactor will be closed and the generator connected to the bus provided the generator functions normally and provided the throttle switch is closed and 28V DC ground power is not connected.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-26\"><h2 class=\"hotspot-title\">Transformer selector<\/h2><div class=\"hotspot-content\"><p>Two transformer-rectifiers - TR1 and TR2 - are utilized for converting 115V AC power delivered by the engine driven alternators (or by a 115V AC ground power source) into 28V DC. The TRANSFO 26V switch is used to connect either one of the transformers to VP5. The switch has two positions labelled 1 and 2. VP5 for instance powers the control surface pos. indicator, fuel pressure and flap position indicator.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-27\"><h2 class=\"hotspot-title\">Inverter voltmeter<\/h2><div class=\"hotspot-content\"><p>The voltmeter can be connected to VP3 or VP4 by placing the INVERTER VOLTAGE selector in position PHASE A or PHASE C<br \/>\nrespectively. Many instrument gauges use 26V \/ 400hz.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-28\"><h2 class=\"hotspot-title\">Transformer Voltage<\/h2><div class=\"hotspot-content\"><p>The voltmeter can also be connected to VP5 for check of the 115\/26V transformer voltage . This is accomplished by depressing the VOLTM TRANSFO button located below the voltmeter.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-29\"><h2 class=\"hotspot-title\">Generator trip warning<\/h2><div class=\"hotspot-content\"><p>This warning circuit will be energized whenever a generator main circuit breaker trips due to a failure in the generator system. The circuit will then activate the following warnings:<br \/>\n- The red warning light for the affected generator.<br \/>\n- The GENE master warning light and the chime.<br \/>\nA tripped main circuit breaker will also open the generator field circuit and the generator main contactor.<br \/>\nGenerator voltage and load will drop to zero and the magnetic indicator will show that the generator has been disconnected from the bus.<br \/>\nThe warning lights will go out and the chime will be rearmed when the corresponding generator control switch is placed in OFF position.<br \/>\nNOTE: It should be observed that the generator trip warning circuit will not be activated when the generator was manually disconnected. Voltage will be displayed however.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-30\"><h2 class=\"hotspot-title\">Generator trip warning test<\/h2><div class=\"hotspot-content\"><p>Each generator trip warning circuit can be tested by depressing this button. the GENE warning light on UP5 will illuminate, a chime sound and the red warning light to the right of this button illuminate.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-31\"><h2 class=\"hotspot-title\">Ammeter stand-by batteries<\/h2><div class=\"hotspot-content\"><p>Shows amperage drawn or delivered to the stand-by batteries.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-32\"><h2 class=\"hotspot-title\">PP21<\/h2><div class=\"hotspot-content\"><p>Power the following systems:<br \/>\nLH airfoil de-Ice valve<br \/>\nDe-icini duct temp. indicator<br \/>\nLH servodyne heating<br \/>\nServodyne &amp;. Brake chute comp. temp. lnd.<br \/>\nServodyne overheat warning<br \/>\nRadio ventilation valve<br \/>\nCockpit duct &amp;. amb temp. ind.<br \/>\nLH oil temp. indicator<br \/>\nUi Nozzle pos. indicator<br \/>\nLH Fuel press. and level warnings<br \/>\nLH main fuel pump No. 2<br \/>\nForward entrance light<br \/>\nDoor opening allowed light<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-33\"><h2 class=\"hotspot-title\">PP22<\/h2><div class=\"hotspot-content\"><p>Powers the following systems:<br \/>\nAirfoil half capacity relay<br \/>\nRH Airfoil de-ice valve<br \/>\nAirfoil de-Ice temp. control<br \/>\nLeading edge temp. indicator<br \/>\nOAT indicator<br \/>\nRH servodyne heat<br \/>\nCabin duct &amp; ambi. temp. indicators<br \/>\nRadio ventilation control<br \/>\nRH oil temp. indicator<br \/>\nRH nozzle pos. indicator<br \/>\nRH fuel press. and level warnings<br \/>\nRH main fuel pump No. 2<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-34\"><h2 class=\"hotspot-title\">PP23<\/h2><div class=\"hotspot-content\"><p>Powers the following systems:<br \/>\nVOR1<br \/>\nGlide Path 1<br \/>\nADF 1<br \/>\nRadio lights<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-35\"><h2 class=\"hotspot-title\">PP24<\/h2><div class=\"hotspot-content\"><p>Powers the following systems:<br \/>\nVHF2<br \/>\nVOR2<br \/>\nGlide Path 2<br \/>\nADF2<br \/>\nRadio lights<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-36\"><h2 class=\"hotspot-title\">PP11 Essential Bus<\/h2><div class=\"hotspot-content\"><p>Powers nearly everything - the list would be too long.<\/p>\n<\/div><\/div><div class=\"hotspot-info\" id=\"hotspot-hotspot-6485-37\"><h2 class=\"hotspot-title\">Magnetic Indicator<\/h2><div class=\"hotspot-thumb\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"181\" src=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/magindi-on-300x181.jpg\" class=\"attachment-medium size-medium\" alt=\"\" srcset=\"https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/magindi-on-300x181.jpg 300w, https:\/\/www.flycaravelle.com\/wp-content\/uploads\/2016\/01\/magindi-on.jpg 434w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/div><div class=\"hotspot-content\"><p>Shows a line when the stand-by battery bus poweres the normal battery bus.<\/p>\n<\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Some basic info about the electrical system can be found here:<\/p>","protected":false},"author":1,"featured_media":0,"parent":6021,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6496","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/pages\/6496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/comments?post=6496"}],"version-history":[{"count":1,"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/pages\/6496\/revisions"}],"predecessor-version":[{"id":6497,"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/pages\/6496\/revisions\/6497"}],"up":[{"embeddable":true,"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/pages\/6021"}],"wp:attachment":[{"href":"https:\/\/www.flycaravelle.com\/sv\/wp-json\/wp\/v2\/media?parent=6496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}